Schneider Electric Galaxy VM 160–225 kVA (480V) 3-Phase UPS with eConversion up to 99% Efficiency, Modular Battery Options & EcoStruxure IT Integration
Martech Info Systems is a trusted and authorized supplier of Schneider Electric Galaxy VM is a highly efficient 160–225 kVA (480V) 3-phase UPS designed for medium data centers, industrial facilities, healthcare, and critical infrastructure. Featuring up to 99% efficiency in eConversion mode, modular battery options (VRLA, Lithium-ion, NiCad), EcoStruxure IT integration, and scalable redundancy, it ensures reliability, sustainability, and reduced TCO.
-
Schneider Electric Galaxy VS 20–150kW 3-Phase UPS, Modular UPS, High-Efficiency Power Protection with Lithium-Ion or VRLA Batteries
Martech Info Systems is a trusted and authorized supplier of Schneider Electric Galaxy VS is a high-efficiency, modular 10–150kW 3-phase UPS delivering reliable power protection for data centers, IT, and industrial facilities. With up to 99% efficiency in eConversion mode, scalable design, N+1 redundancy, and flexible Lithium-ion or VRLA batteries, it ensures maximum uptime, reduced TCO, and seamless EcoStruxure IT connectivity.
-
Uniflair Indirect Free Cooling Unit with VSD Scroll compressors and EC fans, Downflow, R410A, 50-140 kW
Martech Info Systems is a trusted and authorized supplier of Schneider Electric High efficiency compact units, with latest generation of EC centrifugal fans for indoor installation designed for medium and large data centers.
The range, available in downflow, underfloor, and upflow configurations, is equipped with brushless variable speed scroll compressors and an internal brazed plate condenser to be coupled with an external dry-cooler or a cooling tower.The 7-inch touch screen display enables easy management of complex operations, such as setting operating parameters, monitoring the trend of main working parameters, and reading alarm messages.
-
Uniflair Direct Expansion Water Cooled Unit with Scroll compressors and EC fans, Downflow, R410A, 60-140 kW
Martech Info Systems is a trusted and authorized supplier of Schneider Electric High efficiency compact units, with latest generation of EC centrifugal fans for indoor installation designed for medium and large data centers.
The range, available only in downflow configuration, is equipped with a scroll compressor and an internal brazed plate condenser coupled with an external dry-cooler or a cooling tower.The 7-inch touch screen display allows easy management of complex operations such as setting operating parameters, monitoring main working trends, and reading alarm messages.
-
IDAV 50-150kW Direct Expansion Air Cooled Unit, Downflow,R410A,Variable speed Scroll compressors, EC fans
The Uniflair direct expansion air cooled IDAV serie is designed for precise temperature and humidity control in data centers. These units feature a downflow configuration with discharge options from either the bottom or front, while drawing cool air from the top. Equipped with variable speed scroll compressors. The units are equipped with the latest generation Radical EC Fans for efficiency maximization. The units are equipped with 7-inch Touch screen display interface that allows to set operating parameters, monitor the trend of the main working parameters, and read any alarm messages.
-
Uniflair Chilled Water Unit, EC fans, Downflow, 20-170 kW
High efficiency compact units, with latest generation of EC centrifugal fans for indoor installation
designed for medium and large data centers.
The range, available in downflow and upflow configuration, is equipped with a single or dual
cooling coil with aluminum fins and copper pipes with hydrophilic coating, and the possibility to
choose among different type of valves:
• Two-way or three-way valve with an actuator integrated with the microprocessor.
• Pressure independent balancing control valve.
7-inch touch screen display to manage complex operation with a simple touch, such as set
operating parameters, monitor the trend of the main working parameters, and read any alarm
messages. -
Uniflair Chilled Water Unit, EC fans, Downflow, 140-250 kW
High efficiency compact units, with latest generation of EC centrifugal fans for indoor installation
designed for medium and large data centers.
The range, composed by a cooling coil module and a fan module shipped separately, is available
in underfloor configuration, but with the possibility to be installed directly in the hard floor.
The units are equipped with a single or dual cooling coil with aluminum fins and copper pipes with
hydrophilic coating, and the possibility to choose among different type of valves:
• Two-way or three-way valve with an actuator integrated with the microprocessor
• Pressure independent balancing control valve with integrated flowmeter
7-inch touch screen display to manage complex operation with a simple touch, such as set operating
parameters, monitor the trend of the main working parameters, and read any alarm messages. -
FXCV 130-250kW Chilled Water, Frontal Discharge
New generation of compact front flow chilled water units for no raised floor applications, able to achieve +250kW with high water temperatures, in 2 different versions. InRoom (PA) installation in the white space. InCorridor (TA) installation in the technical corridor. -
Uniflair front flow chilled water, fan wall 200-500kW
High efficiency units, with latest generation of EC centrifugal fans for indoor installation designed for
large data centers.
The range, composed by a single or double module is available for installation in the technical
corridor in modern data center without raised floor.
The units are equipped with cooling coils with aluminum fins and copper pipes with hydrophilic
coating, and the possibility to choose among different type of valves:
• Two-way with an actuator integrated with the microprocessor
• Pressure independent balancing control valve with integrated flowmeter
7-inch touch screen display to manage complex operation with a simple touch, such as set operating
parameters, monitor the trend of the main working parameters, and read any alarm messages. -
APC NetShelter Basic Rack PDU, 1U, 1 phase, 3.7kW 230V 16A or 3.3kW 208V 16A, 12 C13 outlets, C20 cord
Reliable rack power distribution designed to increase manageability and efficiency in the data center The output and input connections are (12)C13 Real-time remote monitoring of connected loads User-defined alarms warn IT and data center managers of potential circuit overloads to prevent accidental power loss to critical equipment. -
APC NetShelter Metered Rack PDU, 2U, 1 phase, 7.4kW 230V 32A, 12 C13 and 4 C19 outlets, IEC 309 inlet
APC Metered Rack PDUs offer resilient power distribution and actively measure, display, and log amperage to support real-time monitoring and historical reporting. This PDU remote monitoring and user-defined alarms to help prevent circuit overloads that can cause accidental power loss to critical equipment. The historical reporting enables users to optimize energy use and plan for capacity with confidence. This PDU can operate at up to 60 degrees Celsius and can be accessed, configured, and managed remotely via EcoStruxure IT, Web, SNMP and Command Line Interface. Power is supplied to the PDU at 200-230 volts via IEC 309 plug with a 3.6m (11 ft) cord while power comes out at 230 volts through (36) IEC 320 C13 and (6) IEC 320 C19 outlets. As a Green Premium product, this unit comes with a verified product environment profile, including carbon footprint, scope 3 emissions and end of life instructions.
-
Rack PDU 2G, Metered-by-Outlet, ZeroU, 11.0kW, 230V, (21) C13 & (3) C19
APC Metered by Outlet Rack Power Distribution Units (PDUs) provide individual outlet power metering to enable energy optimization and circuit protection Current metering provides real-time remote monitoring of connected loads Metered by Outlet Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership Metered by Outlet Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers Users can access and configure Metered by Outlet Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency