Uniflair Chilled Water Unit, EC fans, Downflow, 140-250 kW
High efficiency compact units, with latest generation of EC centrifugal fans for indoor installation
designed for medium and large data centers.
The range, composed by a cooling coil module and a fan module shipped separately, is available
in underfloor configuration, but with the possibility to be installed directly in the hard floor.
The units are equipped with a single or dual cooling coil with aluminum fins and copper pipes with
hydrophilic coating, and the possibility to choose among different type of valves:
• Two-way or three-way valve with an actuator integrated with the microprocessor
• Pressure independent balancing control valve with integrated flowmeter
7-inch touch screen display to manage complex operation with a simple touch, such as set operating
parameters, monitor the trend of the main working parameters, and read any alarm messages. -
FXCV 130-250kW Chilled Water, Frontal Discharge
New generation of compact front flow chilled water units for no raised floor applications, able to achieve +250kW with high water temperatures, in 2 different versions. InRoom (PA) installation in the white space. InCorridor (TA) installation in the technical corridor. -
Uniflair front flow chilled water, fan wall 200-500kW
High efficiency units, with latest generation of EC centrifugal fans for indoor installation designed for
large data centers.
The range, composed by a single or double module is available for installation in the technical
corridor in modern data center without raised floor.
The units are equipped with cooling coils with aluminum fins and copper pipes with hydrophilic
coating, and the possibility to choose among different type of valves:
• Two-way with an actuator integrated with the microprocessor
• Pressure independent balancing control valve with integrated flowmeter
7-inch touch screen display to manage complex operation with a simple touch, such as set operating
parameters, monitor the trend of the main working parameters, and read any alarm messages. -
APC NetShelter Basic Rack PDU, 1U, 1 phase, 3.7kW 230V 16A or 3.3kW 208V 16A, 12 C13 outlets, C20 cord
Reliable rack power distribution designed to increase manageability and efficiency in the data center The output and input connections are (12)C13 Real-time remote monitoring of connected loads User-defined alarms warn IT and data center managers of potential circuit overloads to prevent accidental power loss to critical equipment. -
APC NetShelter Metered Rack PDU, 2U, 1 phase, 7.4kW 230V 32A, 12 C13 and 4 C19 outlets, IEC 309 inlet
APC Metered Rack PDUs offer resilient power distribution and actively measure, display, and log amperage to support real-time monitoring and historical reporting. This PDU remote monitoring and user-defined alarms to help prevent circuit overloads that can cause accidental power loss to critical equipment. The historical reporting enables users to optimize energy use and plan for capacity with confidence. This PDU can operate at up to 60 degrees Celsius and can be accessed, configured, and managed remotely via EcoStruxure IT, Web, SNMP and Command Line Interface. Power is supplied to the PDU at 200-230 volts via IEC 309 plug with a 3.6m (11 ft) cord while power comes out at 230 volts through (36) IEC 320 C13 and (6) IEC 320 C19 outlets. As a Green Premium product, this unit comes with a verified product environment profile, including carbon footprint, scope 3 emissions and end of life instructions.
-
Rack PDU 2G, Metered-by-Outlet, ZeroU, 11.0kW, 230V, (21) C13 & (3) C19
APC Metered by Outlet Rack Power Distribution Units (PDUs) provide individual outlet power metering to enable energy optimization and circuit protection Current metering provides real-time remote monitoring of connected loads Metered by Outlet Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership Metered by Outlet Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers Users can access and configure Metered by Outlet Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency
-
Rack PDU 2G, Metered-by-Outlet, ZeroU, 16A, 100-240V, (21) C13 & (3) C19
APC Metered by Outlet Rack Power Distribution Units (PDUs) provide individual outlet power metering to enable energy optimization and circuit protection Current metering provides real-time remote monitoring of connected loads Metered by Outlet Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership Metered by Outlet Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers Users can access and configure Metered by Outlet Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency
-
APC Rack PDU 9000 Switched, ZeroU, 16A, 230V, (21) C13 & (3) C19, IEC309 Cord
It is a switched rack PDU with a maximum current capacity of 16A and an input voltage of 230V. It features 21 IEC 60320 C13 outlets and 3 IEC 60320 C19 outlets, connected via an IEC 60309 16A 2P + E and IEC 60320 C20 plug. The PDU is designed for ZeroU mounting, making it space-efficient for rack installations. It is certified by EAC, EN 55022 class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC part 15 class A, ICES-003, RCM, and VDE. -
APC NetShelter Switched Rack PDU, 1U, 1PH, 3.7kW 230V 16A or 3.3kW 208V 16A, 8 C13 outlets, C20 cord
This APC Switched Rack PDU power distribution unit has a wide range of standardized PDU features that increase network efficiency, manageability and functionality. The output and input connections are (8)C13. Network management capabilities allow you to configure and manage rack PDUs from remote locations. It has has a local current monitoring display that gives a visible warning in case of an overload. The remote individual outlet control provides real-time monitoring of connected loads. It has a multi-tier user access that enables you to restrict unauthorized use of outlets. This rack has a single input power source making it easy to install.
-
APC Rack PDU, 2G, metered by outlet, with switching, 0U, 30A, 200V and 208V, 21 C13 and 3 C19 sockets
APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets Power sequencing delays allow users to define the order in which to power up or down attached equipment Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding Current metering provides real-time remote monitoring of connected loads Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles User-defined alarms warn of potential circuit overloads before critical IT failures occur Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager
-
APC NetShelter Metered-by-Outlet with Switching Rack PDU, 2G, 0U, 11.0kW, 230V, 21 C13 and 3 C19 outlet
APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets Power sequencing delays allow users to define the order in which to power up or down attached equipment Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding Current metering provides real-time remote monitoring of connected loads Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles User-defined alarms warn of potential circuit overloads before critical IT failures occur Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager
-
Rack PDU Blue label kit (Quantity 10 units)
Main Product or component type Label kit Physical Colour Blue Depth 13 mm Height 127 mm Net weight 0.11 kg Width 127 mm Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 12.7 cm Package 1 Width 1.3 cm Package 1 Length 12.7 cm Package 1 Weight 0.11 kg Contractual warranty Warranty 2 years repair or replace