Power Audit Services Martech Info Systems

Monitor the Electrical Health of Your Enterprise with Expert Power Quality Audits

In today’s technology-driven business environment, power quality plays a critical role in ensuring uninterrupted operations and protecting sensitive equipment. At Martech Info Systems, we offer specialized Power Quality Audit Services designed to identify and address electrical issues before they impact your facility’s performance and your organization’s bottom line.

“Find power quality problems before they find you!” 

What is a Power Quality Audit?

A Power Quality Audit is a comprehensive evaluation of your electrical distribution system, measuring key parameters that influence stability, efficiency, and reliability. Our audit follows industry standards such as IEEE 1100, IEC 61558, EN61000, and others, ensuring your facility’s power systems meet global benchmarks.

Power Quality Parameters We Monitor

Our Power Quality Audit Covers All Critical Parameters to Ensure Complete Electrical Health:

  • Voltage & Frequency Stability – Identify fluctuations that can affect equipment performance 
  • Wire Gauge Verification – Ensure proper sizing to prevent overheating and energy loss 
  • Thermal Temperature Monitoring – Detect hotspots that indicate potential failures 
  • Total Harmonic Distortion (Voltage & Current) – Assess distortion levels impacting sensitive loads 
  • Power Factor & Displacement Factor – Measure efficiency and reactive power usage 
  • Load & Neutral Current Analysis – Identify unbalanced or excess current issues 
  • Active, Reactive & Apparent Power Measurement – Understand true power consumption patterns 
  • Surge, Swell, Sag & Frequency Deviations – Detect disturbances causing operational risks 
  • High-Voltage Transient Impulses – Capture damaging spikes from switching or lightning 
  • Flicker Level & Crest Factor – Measure fluctuations affecting lighting and equipment stability 
  • Phase Voltage Unbalance – Identify uneven load distribution across phases 
  • Neutral-to-Ground Potential Differences – Ensure safety and compliance with grounding standards 

Power Quality Audit Checklist

Initial Data Collection & Customer Input

  • Understand customer’s power quality issues and concerns 
  • Define audit objectives and scope 
  • Collect facility electrical drawings, equipment inventory, and load information 
  • Identify critical equipment and processes impacted by power quality issues 

Visual & Physical Inspection

  • Inspect electrical wiring for proper grounding and bonding 
  • Check condition of panels, switchboards, MCCBs, MCBs, ELCBs 
  • Verify installation of surge arresters and lightning protection devices 
  • Confirm availability and condition of emergency lighting in electrical rooms 

Power Quality Parameter Measurements

  • Measure Voltage (RMS) and Frequency 
  • Monitor Total Harmonic Distortion (THD) for voltage and current 
  • Check Power Factor and Displacement Factor 
  • Measure Load current, Neutral current, and Phase voltage unbalance 
  • Record Active Power (kW), Reactive Power (kVAR), and Apparent Power (kVA) 
  • Capture Voltage sags, swells, surges, and transients 
  • Measure Flicker levels and Crest factor 
  • Check Neutral to ground voltage differences 

Electrical System Performance

  • Review UPS, Servo/Stabilizer, DG set output power quality 
  • Evaluate harmonic content and sources in the electrical network 
  • Assess phase balancing and load distribution 
  • Analyze surge and transient event history 
  • Conduct Load testing under typical and peak load conditions 
  • Perform Reactive Power Analysis and power factor optimization check 

Equipment Condition & Protection Systems

  • Inspect battery health and UPS backup performance 
  • Validate lightning arrester placements and surge protection devices 
  • Check for loose connections, overheating, or corrosion on switchgear 
  • Verify cable sizing and panel ratings according to load demands 

Safety & Compliance

  • Confirm compliance with relevant standards: IEEE 1100, IEC 61558, EN61000, IS codes 
  • Check for proper earthing and grounding resistance values 
  • Verify adherence to electrical safety protocols and preventive maintenance schedules 

Report & Recommendation Preparation

  • Summarize findings and deviations 
  • Identify root causes of power quality problems 
  • Recommend corrective actions: Harmonic filters, capacitor banks, APFC, TVSS installations 
  • Suggest energy saving and power factor correction opportunities 
  • Develop a prioritized action plan for improvement 

How Power Quality Problems Affect Your Business

Poor power quality can lead to a spectrum of challenges, including:

  • Higher energy consumption and increased costs 
  • Penalties for exceeding utility tariffs 
  • Production downtime causing quality and quantity losses 
  • Premature equipment failure and reduced lifecycle 
  • Increased maintenance expenditure 
  • Over-sizing of equipment leading to additional capital outlay 
  • Electrical malfunctions such as overvoltage, undervoltage, surges, spikes, and noise 

Scope of Our Power Quality Audit Services

Electrical Harmonic Analysis and Survey

  • On-site data collection of voltage/current harmonics 
  • Three-phase system balancing study 
  • Voltage stability and improvement analysis 
  • Surge and transient protection evaluation 
  • Broadband harmonic reduction recommendations 

Harmonic Analysis

Using advanced simulation software, we identify existing and potential harmonic distortions and recommend effective mitigation techniques.

Surge & Transient Analysis

Recording and analysing transient events ranging from 1KV to 6KV to evaluate their impact.

Voltage Dips & Swells Analysis

Monitoring short-term voltage variations for their magnitude and duration.

Reactive Power & Load Flow Analysis

Calculating precise reactive power needs, optimizing power factor at the point of common coupling (PCC), and predicting power flows and losses to improve system efficiency.

Captive Power Analysis

Evaluating captive power synchronization to reduce peak demand charges and fuel consumption.

Solutions We Provide

  • Tuned & Detuned Active/Passive Harmonic Filters 
  • Power Factor Correcting Capacitors (APFC) 
  • Transient Voltage Surge Suppressors (TVSS) 
  • Power Quality Monitoring Meters 
  • UPS/Inverters Installation & Maintenance 
  • Peak Demand Management Systems 
  • Power Factor Controllers 

Benefits of Power Quality Audits

  • Improved Equipment Efficiency & Lifespan: Prevent overheating and premature failures. 
  • Reduced Maintenance & Downtime: Identify issues proactively for scheduled servicing. 
  • Energy Savings: Minimize waste and lower electricity bills. 
  • Enhanced Safety: Mitigate risks of electrical fires and equipment damage. 
  • Compliance Assurance: Meet industry standards and avoid penalties. 
  • Data-Driven Decisions: Empower investments in upgrades, expansions, and energy management. 
  • Stable & Reliable Power: Support critical operations with consistent power quality. 

Why Choose Martech Info Systems for Your Power Audit?

  • Experienced engineers certified in power quality monitoring and diagnostics 
  • Use of cutting-edge power quality analyzers and software tools 
  • Comprehensive reports with actionable insights 
  • Tailored audit plans for industries like manufacturing, IT, healthcare, education, and commercial buildings 
  • Commitment to improving your operational efficiency and reducing costs 

Contact Us Today for a Professional Power Quality Audit

Ensure your critical operations remain stable 24/7 with Martech Info Systems expert power quality audits.